Design ‘‘C’’ clamp frame for a total clamping force of 20 kN............

Question: 

Design ‘‘C’’ clamp frame for a total clamping force of 20 kN. The cross-section of the frame is rectangular and width to thickness ratio is 2. The distance between the load line and natural axis of rectangular cross section is 120 mm and the gap between two faces is 180 mm. The frame is made of cast steel for which maximum permissible tensile stress is 100 N/mm